SYC-18 PP Duct Air Cooler for Industrial and Commercial Cooling
Hot production floors, workshops and warehouses need more than a fan that simply circulates warm indoor air. Where a project calls for fresh-air cooling and distribution through ductwork, the SYC-18 PP Duct Air Cooler offers a practical evaporative cooling option.
The SYC-18 PP delivers an airflow of 18,000 CMH using a 1.1 kW axial fan system. Its rated air pressure is 180–200 Pa, while the stated cooling coverage is 150–200 m². The model supports top or side air discharge, which gives installers flexibility when connecting the cooler to ductwork.
Alvina supplies this ducted cooling solution for industrial and commercial requirements across UAE and GCC, including Abu Dhabi, Dubai, Sharjah, Saudi Arabia, Riyadh, Jeddah, Dammam, Qatar, Bahrain, Kuwait and Oman.
What is the SYC-18 PP Duct Air Cooler?
The SYC-18 PP is a Duct Air Cooler built around the evaporative cooling principle. Instead of using a conventional refrigerant-based cooling cycle, evaporative cooling passes incoming air through water-wetted cooling media. The air then moves into the connected duct system for distribution around the required area.
For the SYC-18 PP, an axial fan produces a rated airflow of 18,000 CMH. The manufacturer lists a three-phase 220V/415V electrical supply, 50 Hz frequency and manual or remote-control options.
The main advantage of a ducted arrangement is placement flexibility. The cooler itself does not have to stand immediately beside every occupied zone. Contractors can instead design duct routes and outlets according to the building layout and required airflow.
This makes an Industrial Duct Air Cooler particularly relevant to factories, storage buildings, assembly sections and workshops with several working zones.
Key Features SYC-18 PP Duct Air Cooler
- 18,000 CMH airflow: The rated airflow suits substantial industrial and commercial cooling requirements.
- 1.1 kW power: The listed motor power is 1.1 kW.
- Axial fan: An axial fan handles the movement of air through the cooler.
- 180–200 Pa pressure: The available pressure supports ducted air delivery.
- Top or side discharge: Different discharge arrangements provide more freedom during installation.
- Manual or remote operation: The control configuration supports both options.
- Multiple speed settings: Manufacturer literature lists single/12-speed operation.
- Large water reservoir: The manufacturer catalogue lists a 225 L tank for the SYC-18 PP version.
Uses of SYC-18 PP
- Factories: It supplies fresh cooled air to production and working areas.
- Warehouses: It helps circulate cooler air through large storage spaces.
- Workshops: Duct outlets can carry airflow towards occupied work bays.
- Assembly areas: It can distribute air along production and assembly lines.
- Industrial sheds: The system can serve wide indoor spaces through planned ductwork.
- Maintenance facilities: It provides cooling around equipment servicing and repair zones.
- Commercial buildings: It can serve large spaces where evaporative cooling is appropriate.
- Loading areas: It can improve air movement around covered operational sections.
Applications Across UAE and GCC
- Abu Dhabi: Suitable for workshops, maintenance buildings, factories and industrial facilities that require ducted air cooling.
- Dubai: Used in warehouses, production areas and commercial facilities where cooled air needs distribution across different working zones.
- Sharjah: Suitable for manufacturing plants, fabrication workshops and industrial sheds that require continuous airflow.
- Saudi Arabia: Used for industrial cooling in factories, warehouses, workshops and other large working environments.
- Riyadh: Suitable for hot and relatively dry industrial environments where evaporative cooling and proper ventilation can work effectively.
- Jeddah: Used in warehouses, workshops and commercial facilities where site humidity and ventilation conditions support evaporative cooling.
- Dammam: Suitable for manufacturing facilities, maintenance workshops and industrial buildings requiring ducted airflow.
- Qatar: Used in warehouses, workshops, production facilities and other large commercial or industrial spaces.
- Bahrain: Suitable for workshops and industrial facilities where a planned duct system can distribute cooled air.
- Kuwait: Used for factories, warehouses and large working areas that require high-volume air movement.
- Oman: Suitable for industrial sheds, workshops, warehouses and manufacturing facilities requiring duct-based evaporative cooling.
Technical Specification
| Technical Specification |
SYC-18 PP |
| Model |
SYC-18 PP |
| Air Discharge |
Top / Side |
| Power |
1.1 kW |
| Airflow |
18,000 CMH |
| Fan Type |
Axial |
| Voltage |
3 Phase 220V / 415V |
| Frequency |
50 Hz |
| Speed Option |
Single / 12 Speed |
| Control System |
Manual / Remote Control |
| Dimensions |
1020 × 1020 × 950 mm |
| Air Pressure |
180–200 Pa |
| Cooling Area |
150–200 m² |
| Water Tank |
225 L |
| Air Outlet Size |
670 × 670 mm |
These values follow the manufacturer catalogue for the SYC-18 PP model.
Important specification note: One reseller page contains conflicting water-tank information, showing both 30–35 L and 225 L for a three-phase listing. The manufacturer PDF specifically identifies 225 L for SYC-18 PP, so that is the value used above. Confirm the final supplied configuration before publishing procurement documents.
How Does the SYC-18 PP Work?
Air enters the cooling section from outside the building. As it travels through wet evaporative media, some of the water evaporates and absorbs heat from the incoming air. The axial fan then moves the conditioned air towards the outlet. Once connected to ductwork, that airflow can travel to selected areas of the facility.
Because evaporative cooling continually introduces outside air, the building also needs a sensible exhaust path. Doors, windows, louvers or mechanical extraction can allow warm indoor air to leave. Humidity deserves attention as well. Evaporative cooling generally performs better in hot, relatively dry conditions than in highly humid air. Project engineers should therefore consider both local climate and building ventilation before sizing a system.
Standards, Certifications and Compliance
ISO 9001 – Quality Management System
IEC 60335 – Safety of Electrical Appliances
CE Marking Requirements
RoHS Compliance
Frequently Asked Questions
1. What is the airflow of the SYC-18 PP?
The manufacturer’s catalogue specifies an airflow of 18,000 CMH.
2. How much area can the cooler cover?
Its listed cooling area is approximately 150–200 m², although actual results depend on climate, ventilation and site conditions.
3. What type of fan does the SYC-18 PP use?
It uses an axial fan for air movement.
4. Can the cooler connect to ductwork?
Yes, the model is intended for ducted air distribution and has a listed outlet size of 670 × 670 mm.
5. What electrical supply does it require?
The published specification lists 3-phase 220V/415V at 50 Hz.
6. Can I control the unit remotely?
Yes, the listed control options include manual and remote control.
7. Where is the SYC-18 PP available?
Alvina supplies the product for requirements across UAE, Saudi Arabia, Qatar, Bahrain, Kuwait and Oman.
Conclusion
The SYC-18 PP Duct Air Cooler combines an 18,000 CMH airflow rating with a 1.1 kW axial fan, 180–200 Pa air pressure and a duct-ready outlet. Those specifications make it an option worth considering for factories, warehouses, workshops and other spaces where cooled air needs to travel beyond the immediate location of the machine.
Rather than selecting a cooler only by floor area, consider duct length, outlet arrangement, ambient humidity, ventilation and the heat generated inside the building. Correct sizing matters, especially when several zones share the same system.
Alvina supplies industrial air-cooling solutions across Abu Dhabi, Dubai, Sharjah and the wider UAE, as well as Saudi Arabia, Riyadh, Jeddah, Dammam, Qatar, Bahrain, Kuwait and Oman.