SYC-25 PP Duct Air Cooler for Industrial Cooling
SYC-25 PP Duct Air Cooler factories, warehouses and workshops can hold a surprising amount of heat during a working day. Machinery adds to the load, high roofs trap warm air, and ordinary circulation fans may only move that heat from one part of the building to another. A ducted evaporative system offers a different way to handle these conditions.
The SYC-25 PP Duct Air Cooler is intended for industrial and commercial spaces where cooled air needs to travel through ductwork before reaching the occupied area. Instead of placing several portable units around a building, a properly planned installation can carry air towards selected work zones.
Alvina supplies duct air cooling solutions across the UAE and GCC, covering Abu Dhabi, Dubai, Sharjah, Saudi Arabia, Riyadh, Jeddah, Dammam, Qatar, Bahrain, Kuwait and Oman.
What is the SYC-25 PP Duct Air Cooler?
The SYC-25 PP is a Ducted Air Cooler that works on the evaporative cooling principle. Outside air enters the cooling section and passes through water-wetted cooling media. Some of the water evaporates during this process, taking heat from the passing air.
After cooling, the fan pushes the air towards the outlet. Connected ducts then carry it to the required sections of the building.
This operating method differs from conventional refrigerated air conditioning. Evaporative cooling continuously brings in outside air and therefore works together with the building’s ventilation arrangement. Warm indoor air needs a suitable path to escape.
For industrial projects, the duct connection is particularly useful. Air outlets can be positioned around production lines, work bays, storage areas or other occupied sections instead of depending on one direct discharge point.
Key Features SYC-25 PP Duct Air Cooler
- Ducted distribution: Air can be routed towards different sections through a planned duct network.
- Evaporative operation: Water evaporation reduces the temperature of incoming air.
- Industrial configuration: The cooler can form part of factory, warehouse or workshop cooling layouts.
- Fresh-air supply: Operation introduces outside air rather than simply recirculating indoor air.
- Flexible outlets: Contractors can position duct outlets according to the building and work-area layout.
- Large-area application: The system can serve wider working areas when correctly sized.
- Practical cooling method: It avoids the conventional compressor refrigeration cycle used by standard air conditioners.
- Central installation: One correctly selected cooler can feed multiple duct outlets, subject to airflow and pressure calculations.
Uses of SYC-25 PP Duct Air Cooler
- Factories: Supplies cooled fresh air towards manufacturing and production sections.
- Warehouses: Distributes airflow around storage and working zones.
- Workshops: Directs air towards repair, fabrication and maintenance areas.
- Assembly lines: Provides airflow along occupied production sections.
- Industrial sheds: Carries air farther into large enclosed buildings.
- Service centres: Helps deliver fresh air around individual service bays.
- Commercial buildings: Serves suitable large spaces through duct outlets.
- Loading zones: Improves airflow around covered operational areas.
- Production plants: Supports general air movement around heat-generating processes.
Applications Across UAE and GCC
- Abu Dhabi: Industrial facilities can use duct cooling for workshops, maintenance buildings and production areas.
- Dubai: Warehouses and commercial facilities can route cooled air towards selected working zones.
- Sharjah: Fabrication shops and manufacturing units can use an Industrial Duct Air Cooler for planned air distribution.
- Saudi Arabia: Factories and warehouses can use evaporative cooling where local conditions and ventilation are suitable.
- Riyadh: Hot and relatively dry conditions can make evaporative cooling useful for suitable industrial buildings.
- Jeddah: Warehouses and workshops can use duct cooling, although local humidity should form part of system selection.
- Dammam: Industrial plants and maintenance facilities can integrate ducted cooling into their ventilation layouts.
- Qatar: Workshops, warehouses and commercial buildings can use duct-based cooling where project conditions allow.
- Bahrain: Industrial facilities can distribute fresh cooled air through strategically positioned outlets.
- Kuwait: A High Airflow Duct Cooler can support cooling requirements in suitable factories and storage facilities.
- Oman: Industrial sheds, workshops and manufacturing facilities can use evaporative cooling with properly planned ventilation.
Technical Specification
Exact SYC-25 PP technical values were not included in the information provided. To avoid publishing incorrect specifications, the model-specific values should be taken from its current manufacturer datasheet.
| Technical Specification |
Details |
| Product Name |
Duct Air Cooler |
| Model |
SYC-25 PP |
| Air Discharge |
Top / Down |
| Power |
1.5 / 2.2 kW |
| Air Flow |
22,000 / 25,000 CMH |
| Fan Type |
Axial |
| Voltage |
3 Phase, 415V |
| Frequency |
50 Hz |
| Speed Option |
Single Speed |
| Control System |
Manual / Remote Controller |
| Dimensions |
1220 × 1220 × 1150 mm |
| Air Pressure |
180–200 Pa |
| Cooling Area |
200–250 m² |
| Water Tank Capacity |
35–40 L |
| Air Outlet Size |
775 × 775 mm |
How Does the SYC-25 PP Work?
The cooling cycle begins with outside air entering through the wet cooling media. Water absorbs heat as a portion of it evaporates, lowering the temperature of the passing air. The fan then moves this air into the connected duct system. From there, outlets distribute it around the required parts of the facility.
Good ventilation matters. Since evaporation adds moisture and the cooler continuously introduces outside air, warm indoor air needs somewhere to leave. Open doors, louvers, windows or mechanical extraction may form part of the overall design.
Ambient humidity also affects performance. A project engineer should therefore consider temperature, relative humidity, building size, heat load, required airflow and duct resistance before selecting the final configuration.
Standards, Certifications and Compliance
The links above are standards and regulatory references, not confirmation that every SYC-25 PP configuration holds those certifications. Request the applicable manufacturer certificates and declarations for the unit being supplied.
Why Choose SYC-25 PP from Alvina?
- Regional supply: Alvina serves industrial requirements across the UAE and GCC.
- Industrial applications: The cooler can suit factories, workshops, warehouses and other large facilities.
- Duct compatibility: The layout allows air to reach areas away from the cooler itself.
- Fresh-air cooling: The evaporative process works with incoming outside air.
- Project-based selection: The final unit can be assessed against airflow, ducting and site requirements.
- Wide GCC coverage: Supply requirements can be handled for UAE, Saudi Arabia, Qatar, Bahrain, Kuwait and Oman.
Frequently Asked Questions
1. What is the SYC-25 PP Duct Air Cooler?
It is a duct-type evaporative cooler intended for industrial and commercial air-cooling applications.
2. Where can the SYC-25 PP be used?
Typical applications include factories, warehouses, workshops, production areas and industrial sheds.
3. Can the cooler work with a duct system?
Yes, its ducted configuration allows cooled air to travel towards selected areas through connected ductwork.
4. Does an evaporative cooler use refrigerant?
No, evaporative cooling primarily uses water evaporation to remove heat from incoming air.
5. Does humidity affect cooling performance?
Yes, evaporative cooling generally achieves a greater temperature reduction when the incoming air is relatively dry.
6. Can it cool several working zones?
A properly engineered duct system can supply several outlets, provided the cooler’s airflow and available pressure meet the design requirements.
7. Where does Alvina supply the SYC-25 PP?
Alvina supplies industrial cooling solutions across UAE, Saudi Arabia, Qatar, Bahrain, Kuwait and Oman.
Conclusion
The SYC-25 PP Duct Air Cooler provides a practical way to combine evaporative cooling with planned air distribution. Rather than restricting airflow to the immediate area around the machine, ductwork can carry fresh cooled air towards specific work zones.
Factories, warehouses, fabrication shops, maintenance facilities and other large buildings can benefit from this approach when site conditions suit evaporative cooling.
Correct selection remains important. Airflow, available pressure, duct length, building heat load, humidity and ventilation should all be checked before installation. Alvina supplies duct cooling solutions for industrial and commercial projects throughout the UAE and wider GCC.